AVS 59th Annual International Symposium and Exhibition
    Vacuum Technology Tuesday Sessions
       Session VT-TuP

Paper VT-TuP7
PLS-II Vacuum System Commissioning

Tuesday, October 30, 2012, 6:00 pm, Room Central Hall

Session: Vacuum Technology Poster Session and Student-built Vacuum System Poster Competition
Presenter: C.D. Park, Pohang University of Science and Technology, Republic of Korea
Authors: C.D. Park, Pohang University of Science and Technology, Republic of Korea
S. Chung, Pohang University of Science and Technology, Republic of Korea
T. Ha, Pohang University of Science and Technology, Republic of Korea
C.K. Kim, Pohang University of Science and Technology, Republic of Korea
M.S. Hong, Pohang University of Science and Technology, Republic of Korea
H.C. Kwon, Pohang University of Science and Technology, Republic of Korea
Y.D. Joo, Pohang University of Science and Technology, Republic of Korea
Correspondent: Click to Email

è Pohang Light Source’s upgraded machine (PLS-II) has been on commissioning stage since the installation completed in June 2011. PLS-II storage ring vacuum system is designed to maintain a base pressure in the low 10-9 Torr region for the beam-gas scattering lifetime in excess of 20 hours, and the vacuum components, especially photon absorbers, are designed to endure 3 GeV, 400 mA beam operation. Several issues regarding the vacuum system will be presented, such as BPM stability from mechanical or electrical point of view, vacuum chamber displacement, photon absorbers, and vacuum related events during the commissioning.