AVS 57th International Symposium & Exhibition
    Surface Science Tuesday Sessions
       Session SS-TuP

Paper SS-TuP9
Surface Roughness of Anodized Titanium Coatings

Tuesday, October 19, 2010, 6:00 pm, Room Southwest Exhibit Hall

Session: Surface Science Poster Session
Presenter: D.A. Chinn, Sandia National Laboratories
Authors: D.A. Chinn, Sandia National Laboratories
M.T. Dugger, Sandia National Laboratories
Correspondent: Click to Email

Samples of grade five 6Al4V titanium alloy were coated with two commercial fluoropolymer anodizations (Tiodize and Canadize) and compared. Neither coating demonstrates significant outgassing. The coatings show very similar elemental analysis, except for the presence of lead in the Canadize coating, which may account for its lower surface friction in humid environments. Surface roughness has been compared by SEM, contact profilometry, optical profilometry, power spectral density and bidirectional scattering distribution function (BSDF). The Tiodize film is slightly smoother by all measurement methods, but the Canadize film shows slightly less scatter at all angles of incidence. Both films exhibited initial friction coefficients of 0.2 to 0.4, increasing to 0.4 to 0.8 after 1000 cycles of sliding due to wear of the coating and ball. The coatings are very similar and should behave identically in most applications.