AVS 56th International Symposium & Exhibition | |
Vacuum Technology | Wednesday Sessions |
Session VT-WeA |
Session: | Modeling and Accelerators |
Presenter: | J.R. Chen, NSRRC and NTHU, Taiwan |
Authors: | J.R. Chen, NSRRC and NTHU, Taiwan G.Y. Hsiung, National Synchrotron Radiation Research Center, Taiwan C.C. Chang, National Synchrotron Radiation Research Center, Taiwan C.L. Chen, National Synchrotron Radiation Research Center, Taiwan C.K. Chan, National Synchrotron Radiation Research Center, Taiwan H.P. Hsueh, National Synchrotron Radiation Research Center, Taiwan C.M. Cheng, National Synchrotron Radiation Research Center, Taiwan C.Y. Yang, National Synchrotron Radiation Research Center, Taiwan |
Correspondent: | Click to Email |
A design and prototype of the vacuum system of a low-emittance 3 GeV synchrotron light source, the Taiwan Photon Source (TPS, with a circumference of 518.4m ), is described. The TPS vacuum system has low-outgas aluminum beam ducts, low impedance structure, oil-less pumping system and oil-less fabrication process. Little dust, a stable mechanical structure and high reliability components are also equipped in the vacuum system. A 14 m long prototype of the TPS vacuum system was fabricated. Two 4 m long bending-magnet chambers were made by the CNC machining process, lubricated with ethyl alcohol to protect the aluminum surface from oil contamination. Ozonated water cleaning process was applied to reduce the photo-desorption rate from the chamber surface. The design considerations, the critical factors in fabrication and the test results of the vacuum system prototype are presented.