Pacific Rim Symposium on Surfaces, Coatings and Interfaces (PacSurf 2016)
    Biomaterial Surfaces & Interfaces Tuesday Sessions
       Session BI-TuP

Paper BI-TuP1
A Real Time Observation of Nano/Bio Interface of Protein Nanoparticles Using Graphene Liquid Cell ELectron Microscopy

Tuesday, December 13, 2016, 4:00 pm, Room Mauka

Session: Biomaterial Surfaces & Interfaces Poster Session
Presenter: Tolou Shokuhfar, University of Illinois at Chicago, USA
Correspondent: Click to Email

Investigation of crystalline structure and chemistry of biomaterials including biopolymers, bacteria cultures and proteins has always been a great interest for both materials and biomedical communities. The difficulties associated with the imaging of biological structures can be listed as follows: 1) If the imaging is conventional in Scanning / Transmission Electron Microscope (S/TEM), all liquid phase will be evaporated in the vacuum environment when inserted into the microscope, otherwise room temperature fixation, dehydration, infiltration, fixation, embedding and staining should be applied, but in this case, the sample will go through several chemical and thermal processes which involves loss of liquid phase and artificial contrast improvement through preferential staining so that the sample will not be in its native state. 2) If cryogenic imaging is utilized, the sample will be frozen, so all these steps mentioned in 1 will be eliminated. By lowering diffusion rates at liquid nitrogen temperatures, the electron beam induced sample damage will be less, which is good for imaging, but the other energy activated processes, which again depend on the electron beam-sample interaction, are not possible for these frozen samples to occur. 3) In order to see the dynamic processes, in situ fluid cell holders can be used. Even though electron beam related dynamic processes can be visualized with these holders, the sample thickness will be too much including the two silicon nitride windows and the liquid sandwiched in between the windows. 4) To characterize the chemistry and crystal structure knowledge at the native state with the highest resolution, the material needs to be thin and should be sealed/sandwiched in between two single layers of graphene sheets forming graphene liquid cell (GLC), so that the Selected Area Electron Diffraction (SAED) and Electron Energy Loss Spectroscopy (EELS) studies can be carried out in the Cs corrected S/TEMs with the highest resolution available in terms of the crystal structure and chemistry, respectively. We have shown even individual iron ions can be detected in the liquid state when released from the ferritin structures encapsulated in GLC and which proves the necessity of using GLC for the achievement of this sort of resolution [1-2].

[1] T Shokuhfar et al.: High resolution electron microscopy and spectroscopy of ferritin in biocompatible liquid cells and graphene sandwiches, Advanced Materials, 26, 3410, pp. 3410-3414.

[2] The authors acknowledge funding from the National Science Foundation- CAREER award- Grant No- DMR- 1350734.