Robust High-Resolution Imaging and Quantitative Force Spectroscopy in Vacuum with Tuned-Oscillator Atomic Force Microscopy

Monday, October 30, 2017, 9:00 am, Room 10

Session: New Imaging and Spectroscopy Methodologies
Presenter: Omur Dagdeviren, Yale University
Authors: O.E. Dagdeviren, Yale University
J. Goetzen, Yale University
H. Holscher, Karlsruhe Institute of Technology (KIT), Germany
E.I. Altman, Yale University
U.D. Schwarz, Yale University
Correspondent: Click to Email

Since the first demonstration of atomic resolution in ultrahigh vacuum more than twenty years ago, frequency modulation-based noncontact atomic force microscopy (FM-NC-AFM) has significantly matured and is now routinely applied to study problems that benefit from high-resolution surface imaging. In FM-NC-AFM, control of the tip’s vertical position is accomplished by detecting a shift in the cantilever’s resonance frequency upon approach to the sample. Consistently ensuring reliable distance control during extended data acquisition periods has nevertheless remained challenging, as most FM-mode-based control schemes employ three feedback loops that may interfere. As a consequence, sample throughput in FM-NC-AFM is often low compared to ambient condition AFM, where the easy-to-implement amplitude-modulation (AM) control scheme is predominantly used. Transfer of the AM methodology to high-resolution measurements in vacuum is, however, difficult as with AM-AFM, instabilities during approach are common. In addition, the lack of viscous air damping and the related significant increase of the cantilever’s quality factor generate prolonged settling times, which cause the system’s bandwidth to become impractical for many applications. Here we introduce a greatly simplified approach to NC-AFM imaging and quantitative tip-sample interaction force measurement that prevents instabilities while simultaneously enabling data acquisition with customary scan speeds by externally tuning the oscillator’s response characteristics [1]. After discussing background and basic measurement principle, examples for its application to a variety of sample systems are provided [1,2,3,4]. A major advantage of this operational scheme is that it delivers robust position control in both the attractive and repulsive regimes with only one feedback loop, thereby carrying the potential to boost the method’s usability.

+ Author for correspondence: omur.dagdeviren@yale.edu

[1] O.E. Dagdeviren et al, Nanotechnology 27, 065703 (2016)

[2] O.E. Dagdeviren et al, Nanotechnology, 27, 485708 (2016)

[3] O.E. Dagdeviren et al, Physical Review B, 93, 195303 (2016)

[4] O.E. Dagdeviren et al, Advanced Materials and Interfaces, 4, 1601011 (2017)